Fluorescent charging of Ecoglo S10 Material (20 lux, 4000K) In A Poorly Lit Area
|
|
| Activation Time | Hours of Visibility* |
| 5 minutes | 0.5 hours |
| 10 minutes | 1 hours |
| 20 minutes | 2.25 hours |
| 30 minutes | 3 hours |
* A luminance level of 5 millicandelas is defined as visible by NYC RS6.1 and ICC
|
Fluorescent charging of Ecoglo S10 Material (150 lux, 4000K) In A Reasonably Lit Area
|
|
| Activation Time | Hours of Visibility* |
| 5 minutes | 2.5 hours |
| 10 minutes | 4 hours |
| 20 minutes | 6 hours |
| 30 minutes | 7 hours |
* A luminance level of 5 millicandelas is defined as visible by NYC RS6.1 and ICC
|
Fluorescent charging of Ecoglo S10 Material (300 lux, 4000K) In A Well Lit Area
|
|
| Activation Time | Hours of Visibility* |
| 5 minutes | 4 hours |
| 10 minutes | 6 hours |
| 20 minutes | 7 hours |
| 30 minutes | 8 hours |
* A luminance level of 5 millicandelas is defined as visible by NYC RS6.1 and ICC